ER-X Quick Start Guide (2)
Power Adapter (12V, 0.5A)
  • For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
  • For outdoor applications, shielded Category 5 (or above) cabling should be used for all wired Ethernet connections. To enhance ESD protection, attach a ground wire (not included) to the back panel of the EdgeRouter.

    We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cable from Ubiquiti. For more details, visit: ui.com/toughcable

  • ER-X Quick Start Guide (3)

    Note: Although the cabling can be located outdoors, the EdgeRouter itself should be housed inside a protective enclosure.

Power Options

The EdgeRouter can be powered by either method:

  • Power adapter
  • 24V passive PoE on the eth0/PoE In port

Passive PoE output on port eth4/PoE Out works as a passthrough and depends on the input power source.

If the included Power Adapter (12V, 0.5A) is used, there may not be sufficient passthrough to power another device because the EdgeRouter can consume up to 5 watts on its own.

We recommend using a more powerful input power source (not included); here are a few examples of viable power input options for passive PoE passthrough:

Power Input

Passive PoE Passthrough

24V passive PoE (on eth0/PoE In)*

≈23V, 5W

12V, 1A
(ERLite-3 Power Adapter)

≈11V, 5W

24V, 2.5A
(ERPoe-5 Power Adapter)

≈23V, 11W

* Not compatible with 24V, 1A Gigabit PoE Adapter.

ER-X Quick Start Guide (4)

ER-X Quick Start Guide (5)

ER-X Quick Start Guide (6)

ER-X Quick Start Guide (7)

Power LED

Off

Power Off

Green

Power On

ER-X Quick Start Guide (8)

Link/Activity LED (eth0 - eth4 Ports)

Off

No Link

Green

Link Established at 10/100/1000 Mbps

Flashing Indicates Activity

ER-X Quick Start Guide (9)

eth0/PoE In Port

RJ45 port accepts 24V passive PoE and supports a 10/100/1000 Ethernet connection.

ER-X Quick Start Guide (10)

eth1 - eth3 Ports

RJ45 ports support 10/100/1000 Ethernet connections.

ER-X Quick Start Guide (11)

eth4/PoE Out Port

RJ45 port supports passive PoE passthrough and a 10/100/1000 Ethernet connection.

ER-X Quick Start Guide (12)

Reset Button

Click here to learn how to reset the EdgeRouter to factory defaults.

ER-X Quick Start Guide (13)

Ground

ESD grounding for enhanced ESD protection. The ground wire and screw with washer are not included (recommended screw size: M3-0.5 x 4 mm).

ER-X Quick Start Guide (14)

Power Port

Connect the Power Adapter.

Follow the appropriate instructions:

Connecting Power Using the Power Adapter

ER-X Quick Start Guide (15)

Connecting Power Using PoE

ER-X Quick Start Guide (16)

OR

ER-X Quick Start Guide (17)

The EdgeOS® configuration interface can be accessed via DHCP or static IP address assignment. By default, eth1 is set up as a DHCP client, while eth0 is assigned a static IP address of 192.168.1.1. To configure the EdgeRouter, proceed to the appropriate section, DHCP or “Static IP Address”.

DHCP

  1. Connect an Ethernet cable from eth1 on the EdgeRouter to a LAN segment that has an existing DHCP server.

    ER-X Quick Start Guide (18)

  2. To check the IP address of the EdgeRouter, use one of the following methods:
    • Set up the DHCP server to provide a specific IP address to the EdgeRouter based on its MAC address (on the label).
    • Let the EdgeRouter obtain an IP address and then check the DHCP server to see which IP address was assigned.
  3. Launch your web browser. Enter the appropriate IP address in the address field. Press enter (PC) or return (Mac).
  4. Enter ubnt in the Username and Password fields. Read the Ubiquiti License Agreement, and check the box next to I agree to the terms of this License Agreement to accept it. Click Login.

The EdgeOS Configuration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax

Static IP Address

  1. Connect an Ethernet cable from the Ethernet port on your computer to the port labeled eth0/PoE In on the EdgeRouter. If you are using PoE, then connect your computer to the EdgeRouter via a PoE switch or to the adapter’s LAN port.

    ER-X Quick Start Guide (19)

  2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.
  3. Launch your web browser. Type https://192.168.1.1 in the address field, and press enter (PC) or return (Mac).
  4. Enter ubnt in the Username and Password fields. Read the Ubiquiti License Agreement, and check the box next to I agree to the terms of this License Agreement to accept it. Click Login.

The EdgeOS Configuration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax

You can also manage your device using the Ubiquiti Internet Service Provider. UISP lets you configure, monitor, upgrade, and back up your devices using a single application. Get started at uisp.ui.com

ER-X

Dimensions

110 x 75 x 22 mm (4.33 x 2.95 x 0.87")

Weight

175g (6.17 oz)

Max. Power Consumption

5W

Power Input

12VDC, 0.5A Power Adapter (Included)
or
24V Passive PoE

Power Supply

External AC/DC Adapter

Supported Voltage Range

9 to 30VDC

Button

Reset

LED

Power, Ethernet 0-4

Processor

Dual-Core 880 MHz, MIPS1004Kc

System Memory

256 MB DDR3 RAM

Code Storage

256 MB NAND

Wall-Mount

Yes

Networking Interfaces

Data/PoE Input Port(1) 10/100/1000 RJ45 Port
Data Ports(3) 10/100/1000 RJ45 Ports
Data/PoE Passthrough Port(1) 10/100/1000 RJ45 Port

Operating Temperature

-10 to 45° C (14 to 113° F)

Operating Humidity

10 to 90% Noncondensing

Certifications

CE, FCC, IC

© Ubiquiti Inc. All rights reserved.

ER-X Quick Start Guide (2024)
Top Articles
Latest Posts
Article information

Author: Terence Hammes MD

Last Updated:

Views: 5837

Rating: 4.9 / 5 (49 voted)

Reviews: 80% of readers found this page helpful

Author information

Name: Terence Hammes MD

Birthday: 1992-04-11

Address: Suite 408 9446 Mercy Mews, West Roxie, CT 04904

Phone: +50312511349175

Job: Product Consulting Liaison

Hobby: Jogging, Motor sports, Nordic skating, Jigsaw puzzles, Bird watching, Nordic skating, Sculpting

Introduction: My name is Terence Hammes MD, I am a inexpensive, energetic, jolly, faithful, cheerful, proud, rich person who loves writing and wants to share my knowledge and understanding with you.